Compare devices

Ventilator comparison. HAMILTON‑C6 versus the others

  • Standard
  • Option
  • Not available
HAMILTON-C6 HAMILTON-C6
HAMILTON-G5/S1
HAMILTON-C3
Patient groupsAdult/Ped, NeonatalAdult/Ped, NeonatalAdult/Ped, Neonatal
Dimensions (W x D x H)423 x 250 x 415 mm (monitor)
360 x 250 x 394 mm (ventilation unit)
640 x 560 x 1400 mm (incl. trolley)
500 x 450 x 440 mm (ventilation unit)
580 x 600 x 1300 mm (min. monitor mounted on rail)
580 x 600 x 1500 mm (max. monitor mounted on rail)
310 x 250 x 460 mm (ventilation unit)
560 x 640 x 1460 mm (incl. trolley)
WeightMonitor (interaction panel) without shelf mount: 7.8 kg (17.2 lb)
Monitor with shelf mount: 10 kg (22 lb)
Ventilation unit with shelf mount: 10.5 kg (23.2 lb)
Ventilation unit, monitor, and trolley: 46 kg (101 lb)
Ventilation unit, monitor, and shelf mount: 38 kg (83.8 lb)
57 kg (125.6 lb) with standard trolley, monitor, and ventilation unit
Ventilation unit: 9.5 kg (21 lb)
Ventilation unit and trolley: 37 kg (81.6 lb)
Monitor size and resolution17 in (431.8 mm) diagonal
1920 x 1200 pixels
15 in (381 mm) diagonal
1024 x 768 pixels
12.1 in (307.3 mm) diagonal
1280 x 800 pixels
Detachable monitor
Battery operating time1.5 h with one battery
3 h with two batteries
1 h with one battery2.4 h with one battery
5 h with two batteries
Hot‑swappable battery
Air supplyIntegrated turbine with warranty for the expected lifetime of the HAMILTON‑C6 ventilatorRequires compressed airIntegrated turbine
O2 connectorDISS (CGA 1240) or NISTDISS (CGA 1240) or NIST (optional), NF (optional)DISS (CGA 1240) or NIST
ConnectivityThree COM ports, two USB ports, DVI, Nurse callCompactFlash, USB, DVI, COM (RS‑232), Special interfaceCOM port, Nurse call (optional)
Loudness37 dB in normal operation38.6 dB in normal operation43 dB in normal operation
Technical specificationsTechnical specificationsTechnical specifications
Volume controlled, flow controlled
Volume targeted, adaptive pressure controlled
Intelligent ventilationASV®, INTELLiVENT®‑ASV® (option)ASV®, INTELLiVENT®‑ASV® (option on HAMILTON‑G5, standard on HAMILTON‑S1)ASV®, INTELLiVENT-ASV® (option)
Noninvasive ventilation
High flow
Comparison of ventilation modes between manufacturers
Visualization of lung mechanics (Dynamic Lung)
Visualization of the patient’s ventilator dependence
Esophageal pressure measurement
Capnography
SpO2 monitoring
Recruitability assessment and lung recruitment (P/V Tool Pro)
Patient‑ventilator synchronization (IntelliSync+)
CPR ventilation
Hamilton Connect Module
Remote connection to HAMILTON‑H900 humidifier
Integrated IntelliCuff cuff pressure controller
Integrated pneumatic nebulizer
Integrated Aerogen nebulizer
Compatibility with Sedaconda ACD‑S anesthetic delivery system