We have detected that you are visiting our website from United States.
We offer a separate version of the website for your country (United States).

Switch to United States
 Products

HAMILTON-HF90. Advanced high flow oxygen therapy

HAMILTON-HF90

Inspired by you. Designed for your patients

The HAMILTON-HF90 is an all-in-one solution for high flow oxygen therapy, providing caregivers with the tools and flexibility needed to tailor treatment to each patient’s unique needs.

A simple solution to enhance patient comfort and enable patient mobility.

HAMILTON-HF90
HAMILTON-HF90

Inspired by you. Designed for your patients

The HAMILTON-HF90 is an all-in-one solution for high flow oxygen therapy, providing caregivers with the tools and flexibility needed to tailor treatment to each patient’s unique needs. A simple solution to enhance patient comfort and enable patient mobility.

HAMILTON-HF90

Advanced therapy. High flow oxygen therapy

  • For all our patient groups: Adult/Ped and Neo/Ped
  • Flow rate from 2–80 l/min
  • Oxygen from 21%–100%
  • Temperature from 31°C–39°C (1°C steps)
HAMILTON-HF90

More than oxygen. Take control of your patient’s therapy

  • Adjust Flow, Oxygen, and Temperature settings
  • Monitor Pulse, Respiratory rate, SpO2, Perfusion Index and PVI with the SpO2 option
HAMILTON-HF90

Stay connected. Connectivity options

  • Nurse Call
  • SpO2 Sensor
  • Nebulizer
  • PDMS
  • COM1
HAMILTON-HF90

Plug and play. Preassembled and ready to use

The safety-lock system secures each connector firmly in place. A simple setup with just two components:

  • Humidification chamber with water line
  • Wall-heated breathing circuit with integrated temperature probe
 HAMILTON-HF90

It keeps going and going. Battery power on

  • The optional battery can run independently for up to two hours (At a Flow rate of 40 l/min, Oxygen of 30%, and Temperature of 37°C)
  • The battery status is shown on the main screen and the battery itself
HAMILTON-HF90

Walk with me. Ideally equipped for intrahospital transport

  • High-quality trolley featuring space for up to three oxygen bottles
  • Sturdy handles on both sides to support the patient
  • Hangers for a water bottle and infusion bags
  • Five easy-to-maneuver wheels for added stability
  • Two standard rails for other accessories
HAMILTON-HF90
HAMILTON-HF90 interface image

I can see clearly now. Intuitive user interface

  • Smooth and responsive multi-touch functionality even with medical gloves
  • Both automatic and manual brightness adjustments
  • Clear and crisp visuals
  • Virtual troubleshooting guidance
HAMILTON-HF90 O2 assist

For trendsetters. The graph trends

With the SpO2 option installed, you can view the following parameters in real-time during the therapy:

  • Flow/Oxygen
  • SpO2/Oxygen
  • SpO2/FiO2 ratio
  • Respiratory rate (Masimo onlya​)
  • ROX index (Masimo onlya​)

The device can store up to 72 hours of monitored data.

Want to see more?
Explore the 3D model

Discover the HAMILTON-HF90 from every angle and click on the hotspots to learn more.

For quick details

Patient groups Adult, pediatric, and neonatal patients
Monitor 5-inch color capacitive touch screen
Flow rate

2–80 l/min
Neo/Ped: 2–30 l/min
Adult/Ped: 4–80 l/min

Oxygen 21%–100%
Temperature

31°C–39°C (in 1°C steps)

SpO2

SpO2 consumables for adult, pediatric, and neonatal patients available. Choose between reusable and single-use products, depending on your institutional policies.

Nebulization

Integrated nebulizer port on the humidification chamber to connect your Aerogen Solo nebulizer. Control the Aerogen Solo nebulizer through the HAMILTON-HF90.

Trolley

High-quality trolley is ideally equipped for intrahospital transport featuring space for up to three oxygen bottles and five easy-to-maneuver wheels for added stability.

Battery

Optional battery can run independently for up to two hours and battery status is shown on the main screen and the battery itsself. An optional battery charger is also available.

Connectivity

The HAMILTON-HF90 offers a serial RS-232 interface and several protocols for connection to patient monitoring systems, patient data management systems (PDMS), and Nurse call, etc.

Download Connectivity: Patient monitoring, EHR/EMR/PDMS (PDF)

Cleaning process The HAMILTON-HF90 is a low-maintenance device. Easy cleaning process with approved cleaning and disinfection wipes.
Oxygen connection Low-pressure oxygen (LPO) connector
High-pressure oxygen (HPO) connector: Connection to either a central gas supply or a gas cylinder with DISS or NIST male gas fittings.
"" ""

For you

Inspired by you. Designed for your patients

The HAMILTON-HF90 is an all-in-one solution for high flow oxygen therapy, providing caregivers with the tools and flexibility needed to tailor treatment to each patient’s unique needs.

Whether in the emergency room, intermediate care, or the ICU, the HAMILTON-HF90 is designed to deliver high flow oxygen therapy whenever required during transfer and mobilization of patients within healthcare facilities.

It combines comprehensive functionality with an intuitive design to support optimal outcomes, enhance patient comfort, and enable patient mobility.

New Learning Hub

Explore our interactive Learning Hub

Learn all about high flow nasal cannula therapy - your way

For the complete solution

Our accessories

We develop our accessories for the highest possible patient safety and ease of use. Whenever possible we integrate them with our devices to simplify operation of the complete system.

Our original consumables

All Hamilton Medical Originals are designed for optimal performance with Hamilton Medical devices. To ensure maximum user satisfaction and patient safety we strive for the highest quality and safety standards.

Photo of an employee

Talk to our experts. Let's discuss your needs

Our team of Ventilation Geeks is happy to assist you in choosing the perfect ventilator for your clinical care setting and help you meet your therapy goals. Get a personalized price quote or schedule a callback for more information.

Footnotes

  • a. Masimo only

References